Modulo Timer Rele Temporizador 0 A 999 Minutos Multifuncion

Modulo Timer Rele Temporizador 0 A 999 Minutos Multifuncion Precio: $7190
Datos del Vendedor:

INFORMATICASANISIDRO

011-47238646
Avenida Andres Rrolon 674, San Isidro

Comprar producto

** INFORMATICA SAN ISIDRO ** ** MercadoLíder Platinum **** COMPONENTES Y MODULOS ELECTRONICOS **** ENVIOS A TODO EL PAIS CON MERCADOENVIOS **Descripción del artículo:Modulo Timer Rele Temporizador De 0 A 999 Minutos ATENCION - LEER ANTES DE COMPRARESTE MODULO POSEE UNA GRAN VARIEDAD DE MODOS DE CONFIGURACION, LO QUE PERMITE VARIOS USOS DISTINTOSES UN MODULO MUY COMPLETO EN LO QUE RESPECTA A SU USO PRACTICO.LAS INSTRUCCIONES DE CONFIGURACION ESTAN COMPLETAS Y CLARAS, PERO ESCRITAS EN INGLES.SI UD NO ENTIENDE LAS INSTRUCCIONES DE COMO CONFIGURARLO POR FAVOR "NO COMPRE ESTE PRODUCTO".NO DAMOS ASISTENCIA SOBRE SU USO O LA CONFIGURACION DEL MISMO PARA SU USO EN PARTICULAR.Un temporizador o Timer es un dispositivo que permite controlar el tiempo de un proceso en especifico como tiempo de llenado de un tanque, tiempo de cocción de un alimento, tiempo de calentamiento en un microondas, tiempo de lavado en una lavadora, etc.El Timer Relay XY-J02 es un timer de alto rendimiento y calidad, muy útil además de ser económico.Cuenta con 3 display de 7 segmentos los cuales permiten ver parámetros como la configuración así como el estado actual del temporizador, además de un LED indicador de estado que se ilumina cuando el equipo esta energizado.Para configurar el timer contamos con 4 micro interruptores o push button, con los cuales podremos desplazarnos a través del menú de opciones del timer, para evitar interferencias asi como retornos de corriente no deseados este módulo cuenta con entradas y salidas optoaisladas que le dan mayor estabilidad y protección a los dispositivos en los que este conectado.Temporizador programableCon aislamiento de optoacopladorCapacidad mejorada de anti interferenciaPlacas de circuito de grado industrialCon 4 orificios para atornillarEspecificacionesVoltaje de alimetación: 6 V a 30V DCSoporta fuente de alimentación: conector Micro USB 5VCorriente de funcionamiento: 50 mACorriente de reposo: 20 mAVoltaje de señal de disparo: 3V a 24VRango de tiempo ajustable: 0.1 segundos - 999 minutos continuamenteIndicador de funcionamiento: LEDCapacidad de salida:Corriente continua: 30V 10ACorriente alterna: 220V 10ADimensiones: 63 X 37 X 18 mmModelo: XY-J02Operating mode:P1: Trigger signal, the relay is on "OP" time, and then disconnect; Within the "OP" time, proceed as follows:P1.1: signal is triggered again, invalidP1.2: signal is triggered again, re-clockingP1.3: Signal is triggered again, relay is disconnected, stop the clock;P-2: Trigger signal, after the "CL" time is off , the "OP" time is on. When the timing is completed, the replay will be disconnected;P3.1: Trigger signal, after the "OP" time is on, the "CL" time is off, then cycle the above actions. If trigger signal within the loop, the relay will be disconnected and stop the clock. The number of cycles ( "LOP ") can be set.P3.2: No need to trigger the signal after powering up, the "OP" time is on, the "CL" time is off, then cycle the above actions; The number of cycles ( "LOP ") can be set.P-4: Signal holding function. If the signal is triggered, timing is cleared, the relay remains on; when the signal disappears, the relay will be off when the "OP" time is over; if another signal is triggered during timing, timing will be cleared.Timing range:0.1 seconds (min.) to 999 minutes (max.) continuously adjustableHow to choose the time range?After setting the parameter values in the mode selection interface, you can choose the timing range by short pressing "STOP" button;XXX. decimal point is in the units digit, timing range: 1 second to 999 seconds.XX. X decimal point is in the tens digit, timing range: 0.1 seconds to 99.9 secondsX. X. X. decimal all light on, timing range: 1 minute to 999 minutes.For example, if you want to set the "OP" time to 3.2 seconds, you can move the decimal point to the place of tens digit, the digital display 03.2Parameter instruction:"OP" - On- time"CL" - Off-time"LOP" - The number of cycles (1-999 times, "---" represents infinite cycles).These parameters are independent, but are shared by each mode. For example, in P1.1 mode, the on-time "OP" is set 5 seconds. If you switch to P1.2 mode, the "OP" time of P1.2 mode will be 5 seconds too.In the main interface (display 000), short press "SET" button, it will display "OP" ( "CL", "LOP") and the corresponding time XXX;If there is only "OP" time in some modes (such as the mode P1.1, P1.2, P1.3), short press the "SET" button to display the “OP” and the corresponding time only;There are "OP", "CL", "LOP" in some modes (such as the mode P3.1, P3.2), short press "SET" button will display "OP" and the corresponding time, “CL” and the corresponding time, “LOP” and the corresponding number of times;After setting the mode, short press "SET" button can check all the set parameters of the mode at present in the main interface , easy and convenient!How to set parameters?1. Determine the operating mode of the relay.2. The current operating mode (P1.1 mode in default) will flash when the module is powered up. Then enter into main interface. In the main interface, long press "SET" button for 2 seconds then release to enter mode selection interface, short press "UP" or "DOWN" button to select the mode (P1.1 ~ P-4) you need.3. After selecting the operating mode (e.g. P3.2), short press the "SET" button to select the parameter to be set. The selected parameter will flash ( "OP" on-time, "CL" off-time, "LOP" cycle times ( "---" represents infinite cycles)), then you can adjust the values by "UP", "DOWN" button to adjust the parameter value, support long press (rapid increase or decrease) and short press (increase or decrease one unit). After finishing adjusting, short press the "STOP" button to select the position of the decimal point , select the timing range (0.1 seconds to 999 minutes). Then short press the "SET" button to enter to set the value of next parameters. Setting procedure is the same as above.4. After setting the parameters, long press "SET" button for 2 seconds then release, the name of the current mode will flash, and then return to the main interface. Parameters setting is completed.The main interface: In the status that the relay is not working, the main interface will display "000" (no decimal point); in the status that the relay is working, there will be a decimal point.Mode selection interface: Long press "SET" button to enter into the mode selection interface, after the setting is completed, long press "SET" button to exit and return to the main screen."STOP" button extensions:Relays enable mode:1. ON: Relay allows conduction in "OP" on-time;2. OFF: relay prohibits conduction and is always closed;In the main interface, short press the "STOP" button to switch between ON and OFF, the current status will flash, and then return to the main interface. (This is emergency stop function, turn off the relay by one button)Sleeping mode:1. "C-P" sleeping mode: If there is no operation in 5 minutes, the digital display will turn off automatically but the program will run as usual;2. "O-d" normal mode: digital display always opens;Long press the "STOP" button for two seconds and then release to switch the mode of "C-P&qu